Serving Industries Across India

Acoustic Treatment Solutions in India

Acoustic Wall Panels, Ceiling Treatment & Acoustic Insulation for DG Rooms, Compressor Rooms, Test Cells, Plants & Offices

Summary: Acoustic treatment is the engineered use of absorptive wall and ceiling systems, acoustic doors, glazing and attenuated ventilation to control noise inside a room and stop it escaping. This page is written for plant heads, EHS managers, architects and facility teams who need acoustic treatment that brings rooms and equipment areas within CPCB and workplace noise limits.

From noise assessment and design to manufacture and installation, SomNandi supplies complete room acoustic systems, including after-sales maintenance and performance inspection.

  • Perforated-sheet faced rockwool systems to IS 8183
  • Acoustic doors up to STC 40 to 50 and acoustic glazing
  • ISO 9001:2015 certified · 150+ projects delivered

SomNandi Industries provides acoustic treatment in India for industrial and commercial spaces: DG rooms, compressor rooms, engine test cells, production halls, offices, auditoriums and studios. Our industrial acoustic systems combine acoustic wall panels, ceiling treatment, acoustic insulation, acoustic doors, soundproof glazing and silent ventilation, engineered to reduce sound transmission and keep noise within CPCB limits. All products are designed and manufactured in-house.

Why Untreated Rooms Become a Noise and Health Problem

Hard concrete, block and metal surfaces reflect machine noise back into the room, raising the level operators work in and pushing noise out through doors, windows and ventilation openings. Long-term exposure to high noise is linked to stress, poor sleep and hearing damage, and it makes communication on the floor harder and less safe.

Keeping noise within the CPCB ambient limits at the boundary, and within workplace exposure limits inside, protects employees’ health and keeps the facility compliant.

What Is Acoustic Treatment?

Acoustic treatment is the use of sound-absorbing surfaces and sound-blocking elements to control how noise behaves in a room. For industrial rooms, SomNandi’s standard system uses a GI channel grid on the walls and ceiling (600 × 900 mm module), filled with tissue-fibre-paper laminated rockwool conforming to IS 8183 and covered with a GI or aluminium perforated sheet. The system is completed with acoustic doors, soundproof glass windows and silent air ventilation that keeps the room fully functional.

For commercial and architectural spaces, treatment is supplied as acoustic wall panels, ceiling tiles, baffles and clouds in polyester fibre, cotton fibre composite, vinyl or cellulose, which are durable, hypoallergenic and easy to maintain.

Acoustic Treatment vs Soundproofing: What Actually Changes?

Short answer: Acoustic treatment absorbs sound inside a room to reduce echo and noise build-up; soundproofing blocks sound from passing through walls, doors and openings. Most noise problems need both.

Absorptive panels lower the noise level inside a DG room, but if the door, window or ventilation opening leaks, noise still escapes. That is why SomNandi treats the room as a complete system, combining absorptive wall and ceiling treatment with acoustic doors, acoustic glazing and acoustic louvers for ventilation.

How Is a DG Room or Compressor Room Acoustically Treated?

Short answer: Walls and ceiling are lined with a perforated-sheet-faced rockwool system, the door is replaced with an acoustic door, windows with soundproof glazing, and air intake and exhaust openings are fitted with attenuated ventilation so the equipment can still breathe.

Where a room cannot be built around the machine, an acoustic enclosure around the equipment itself is usually the faster fix.

Engineering Design and Construction Approach

SomNandi’s room acoustic projects follow six stages: a site noise assessment of sources, room surfaces and openings; selection of the target levels inside and at the boundary; acoustic design of the wall, ceiling, door, glazing and ventilation package; in-house manufacture; installation by trained, safety-equipped teams working to method statements and risk assessments; and after-sales support including maintenance, replacement and performance inspection.

Field Notes: Where Acoustic Treatment Projects Go Wrong

The most common failure is treating the walls and ignoring the openings. A fully lined room with a standard door or an untreated ventilation opening will still leak noise, because sound takes the weakest path. The second is choosing materials on price alone: a foam that suits a studio will not survive the heat, oil and dust of a DG or compressor room, whereas rockwool behind perforated metal will.

Technical Specifications Overview

Technical Parameter Standard Specification Performance Advantage
Framework GI channel grid on wall and ceiling, 600 × 900 mm module Rigid, durable support for infill
Acoustic Infill Tissue-fibre-paper laminated rockwool to IS 8183 High absorption, non-combustible core
Facing GI or aluminium perforated sheet Protects infill in industrial rooms
Acoustic Door Up to STC 40 to 50 Seals the weakest point of the room
Glazing Soundproof glass windows Visibility without noise leakage
Ventilation Silent air ventilation Equipment cooling with low noise
Service Life 10+ years when maintained and used correctly Long-term investment

Technical Data Sheet

Parameter Specification
Product Name Acoustic Treatment System
Wall & Ceiling System GI grid + rockwool (IS 8183) + perforated GI / aluminium sheet
Architectural Panels Polyester fibre, cotton fibre composite, vinyl, cellulose
Doors & Windows Acoustic doors up to STC 40 to 50, soundproof glazing
Typical Rooms DG rooms, compressor rooms, engine test cells, plants, offices
Quality System ISO 9001:2015
After-Sales Maintenance, replacement, performance inspection

Specifications, Benefits, Applications and Installation Process for Acoustic Treatment

1
Framework: GI channel grid, 600 × 900 mm
2
Infill: Laminated rockwool to IS 8183
3
Facing: Perforated GI or aluminium sheet
4
Acoustic Door: Up to STC 40 to 50
5
Glazing: Soundproof glass windows
6
Ventilation: Silent air ventilation
7
Architectural Panels: Polyester, cotton composite, vinyl, cellulose
1
Compliance: Helps meet CPCB and workplace noise limits
2
Worker Health: Lower noise exposure and stress
3
Productivity: Clearer communication on the floor
4
Fire Performance: Non-combustible rockwool core
5
Durability: 10+ years service life with maintenance
6
Low Maintenance: Hypoallergenic, easy-clean panels
7
Single Supplier: Walls, doors, glazing and ventilation together
1
DG Rooms: Generator rooms and power houses
2
Compressor Rooms: Air and gas compressor houses
3
Engine Test Cells: Testing and R&D facilities
4
Production Halls: Factories and manufacturing plants
5
Offices & Halls: Meeting rooms, auditoriums, call centres
6
Studios: Recording and broadcast rooms
1
Noise Assessment: Sources, surfaces and openings surveyed
2
Target Setting: Inside and boundary levels agreed
3
Acoustic Design: Wall, ceiling, door, glazing and ventilation package
4
Manufacture: All products made in-house
5
Installation: Method statements and risk assessments first
6
Verification: Noise levels checked against target
7
After-Sales: Maintenance and performance inspection

Compliance With CPCB and Workplace Noise Limits

Under the Noise Pollution (Regulation and Control) Rules, 2000, CPCB ambient limits are 75 dB(A) by day and 70 dB(A) by night in industrial areas, 65 and 55 dB(A) in commercial areas, 55 and 45 dB(A) in residential areas, and 50 and 40 dB(A) in silence zones. Inside the workplace, programmes are usually built around the 90 dB(A) 8-hour exposure benchmark. SomNandi designs acoustic treatment to the limit that applies to your site, and all products are made under an ISO 9001:2015 quality system.

Related Guides and Case Studies

Frequently Asked Questions

It is the use of sound-absorbing wall and ceiling systems, together with acoustic doors, glazing and ventilation, to control noise inside a room and stop it escaping.

No. Treatment absorbs sound inside a room; soundproofing blocks it from passing through. Most rooms, especially DG and compressor rooms, need both.

For industrial rooms, laminated rockwool to IS 8183 in a GI grid behind perforated GI or aluminium sheet. For commercial spaces, polyester fibre, cotton fibre composite, vinyl or cellulose panels.

Acoustic doors supplied with room treatment are available up to STC 40 to 50.

Price depends on room size, the noise level to reduce, the materials and whether doors, glazing and ventilation are included. SomNandi quotes after a site assessment.

SomNandi products have a service life of more than 10 years when maintained and used correctly.

Yes: maintenance, replacement and performance inspection.

Get an Acoustic Treatment Assessment from SomNandi Industries

Tell us about the room, the equipment inside and the noise level you need to reach, and SomNandi's engineers will recommend a complete acoustic treatment package covering walls, ceiling, doors, glazing and ventilation.

SomNandi Industries

Request a Free Site Noise Assessment »